VOITH SMR Control Servo Motor
Description:
share:
Advantages of VOITH SMR Servo Motor
-
High Dynamic Response — Supports precise actuation in fast servo loops.
-
Excellent Repeatability & Control Accuracy — Ideal for closed-loop hydraulic controls.
-
Heavy-Duty Build — Suitable for high-load industrial applications.
-
Low Maintenance Design — Long operational life with minimal downtime.
-
Compact Structure — Easy system integration, even in restricted installation spaces.
-
Optimized for VOITH Hydraulic Systems — Ensures maximum compatibility and efficiency.
Datasheet
| Parameter | Specification / Value |
|---|---|
| Function / Type | Linear electro-hydraulic actuator (servo motor for valve / flow control) |
| Control input | 4 – 20 mA standard control signal |
| Supply voltage | 24 VDC |
| Current consumption | ~ 1.0 A (max 3.0 A for < 1 s) |
| Effective force (max) | Up to 500 kN [≈ 112,000 lbf] |
| Max. hydraulic pressure | Up to 200 bar [≈ 2,900 psi] |
| Full-stroke closing (trip) time | < 0.3 s |
| Linearity (stroke vs signal) | ± 0.15% of maximum stroke |
| Hysteresis | 0.005% of maximum stroke |
| Reproducibility | 0.015% of maximum stroke |
| Temperature drift (stroke) | 0.04% of maximum stroke per °C |
| Hydraulic fluid (operating medium) | Hydraulic oil per DIN 51524 or turbine oil per DIN 51515. Cleanliness class ISO-VG 4406: 16/13 |
| Oil viscosity range | ISO VG 32 to ISO VG 46 |
| Protection class | IP 65 |
| Ambient operating temperature | –20 to +80 °C (standard version) |
| Optional explosion-proof / hazardous-area rating | ATEX (II 2G IIC T4, Ta = –20 to +60 °C) — other ratings on request |
| Safety / Redundancy options | Redundant design available: position feedback system + way valve control magnets. Fail-safe operation via internal return spring in way valve (and in hydraulic cylinder for single-acting versions) |
| Mean Time Between Failures (MTBF) | > 103 years (calculated per MIL-HDBK-217 and Siemens SN 29500; real-world data indicate equal or better reliability) |
| Typical application fields | Control-valve actuation in steam turbines, gas turbines, compressors; retrofit of mechanical-hydraulic or pneumatic actuators; upgrade of older valve/actuator systems; various industrial hydraulic control applications |